Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1384711.015
Citation: 01001
Citation Type: Serious
Abatement Date: 05/13/2019 2
Initial Penalty: $8,525.00
Current Penalty: $5,967.50
Issuance Date: 03/27/2019
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 5
Report ID: 0729300
Contest Date:
Final Order: 04/11/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/11/2019 | $5,967.50 | 05/13/2019 | Serious | |
Penalty | Z: Issued | 03/27/2019 | $8,525.00 | 05/13/2019 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about 03/13.2019, C.L. Smith Company dba Lyons Blow Molding, located at 8966 Latty Ave., Berkeley, MO, did not conduct an at least annual periodic inspections of their Energy Control (LO/TO) Program. The last review with the authorized employees was dated in July of 2017. The employer had a Blender 104556.14 with electrics and pneumatics, and a Magic Blow Molding Machine 44-10 with electrics, pneumatics and water sources.