Violation Detail
Standard Cited: 19100027 B02 II Scaffolds and rope descent systems.
Inspection Nr: 1382113.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,304.00
Current Penalty: $2,600.00
Issuance Date: 05/03/2019
Nr Instances: 4
Nr Exposed: 3
Abatement Date: 05/13/2019
Gravity: 10
Report ID: 0111400
Contest Date:
Final Order: 05/31/2019
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/31/2019 | $2,600.00 | 05/13/2019 | Serious | |
Penalty | Z: Issued | 05/03/2019 | $5,304.00 | 05/13/2019 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.27(b)(2)(ii): The employer did not ensure rope descent systems were used in accordance with the manufacturer's instructions, warnings, and design limitations or under the direction of a qualified person. Location: Job site The company did not follow rope descent system manufacturers instructions. Instance A: The outrigger gantry head was not secured to the gantry frame or beam. Instance B: A parapet wall was used to 'anchor' a rope descent system without the wall having been structurally analyzed by a registered professional engineer. Instance C: An MIO parapet clamp tie-back was not directly behind the outrigger that it 'served'. Instance D: An MIO parapet clamp was tightened using a pipe instead of hand tightened as required by the manufacturer. Instance E: Rope grabs and rope were not being cleaned in accordance with the manufacturers recommendations.