Violation Detail
Standard Cited: 19100147 D05 I The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1381535.015
Citation: 01001
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $11,934.00
Current Penalty: $0.00
Issuance Date: 08/01/2019
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 10
Report ID: 0626000
Contest Date: 08/20/2019
Final Order: 02/03/2020
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 02/03/2020 | $0.00 | Serious | ||
| Penalty | C: Contested | 08/27/2019 | $11,934.00 | Serious | ||
| Penalty | Z: Issued | 08/01/2019 | $11,934.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(d)(5)(i): All potentially hazardous stored or residual energy was not relieved, disconnected, restrained or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices: At this work site, the employer did not ensure that the pipe being utilized for "pigging" operations was depressurized before the "pig" was removed. This exposed employees to struck by hazards.