Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1379698.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,246.00
Current Penalty: $4,347.40
Issuance Date: 03/07/2019
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 04/23/2019
Gravity: 5
Report ID: 0418100
Contest Date:
Final Order: 03/29/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/29/2019 | $4,347.40 | 04/23/2019 | Serious | |
Penalty | Z: Issued | 03/07/2019 | $7,246.00 | 04/23/2019 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed. On 2/13/19, at the Blairsville facility, the employer did not conduct a periodic inspection of the Lockout program to ensure deficiencies were corrected. Deficiencies found during the inspection included: identification of energies and the magnitude of those energies, identification of the wrong machine and the sizing of the machine.