Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1378083.015
Citation: 01001
Citation Type: Serious
Abatement Date: 07/11/2019 2
Initial Penalty: $13,260.00
Current Penalty: $8,883.00
Issuance Date: 06/28/2019
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 10
Report ID: 0215800
Contest Date: 07/22/2019
Final Order: 03/04/2020
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 03/04/2020 | $8,883.00 | 07/11/2019 | Serious | |
Penalty | C: Contested | 07/23/2019 | $13,260.00 | 07/11/2019 | Serious | |
Penalty | Z: Issued | 06/28/2019 | $13,260.00 | 07/11/2019 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section a) Station Post 4 & 5, on or about 1/24/19: Energy control procedures were not utilized to control hazardous energy when an employee was engaged in cleaning the large cantilever rollers. As a result, the employee suffered a fractured forearm when the steel wool being used for cleaning caught on a powered roller pulling the employee's arm around roller.