Violation Detail
Standard Cited: 19100147 A02 III A The control of hazardous energy (lockout/tagout).
Inspection Nr: 1371253.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $11,934.00
Current Penalty: $7,160.40
Issuance Date: 06/03/2019
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 06/27/2019
Gravity: 10
Report ID: 0214500
Contest Date:
Final Order: 07/19/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/19/2019 | $7,160.40 | 06/27/2019 | Serious | |
Penalty | Z: Issued | 06/03/2019 | $11,934.00 | 06/27/2019 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(a)(2)(iii)(A): Employees work on power source which was not under the exclusive control of the operator. a) Production Area: The Repak RE25 meat packaging machine power source was not under the exclusive control of the machine operator, on 1/14/2019.