Violation Detail
Standard Cited: 19100333 C03 III A Selection and use of work practices
Inspection Nr: 1370348.015
Citation: 01001
Citation Type: Serious
Abatement Date: 07/11/2019 2
Initial Penalty: $13,260.00
Current Penalty: $10,608.00
Issuance Date: 06/21/2019
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): A
Gravity: 10
Report ID: 0625700
Contest Date:
Final Order: 07/12/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/12/2019 | $10,608.00 | 07/11/2019 | Serious | |
Penalty | Z: Issued | 06/21/2019 | $13,260.00 | 07/11/2019 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.333(c)(3)(iii)(A): Vehicles or mechanical equipment capable of having parts of their structures elevated near energized overhead lines were not operated so that a clearance of 10 feet (305 cm) was maintained. a) On or about January 28, 2019, on the USPS facility parking lot at 1701 Shannon St. Monroe, LA 71201, the employer failed to ensure that the employee(s) maintained a clearance of 10 feet from energized high voltage service lines while working from a JLG aerial lift (Model T500J S/N 0030008931).