Violation Detail
Standard Cited: 19100147 D04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1365768.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $9,282.00
Current Penalty: $5,400.00
Issuance Date: 04/16/2019
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 07/01/2019
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order: 05/07/2019
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/07/2019 | $5,400.00 | 07/01/2019 | Serious | |
| Penalty | Z: Issued | 04/16/2019 | $9,282.00 | 05/06/2019 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: On or about December 14, 2018, an employee was exposed to a machine hazard associated with moving parts and an in-going nip point hazard during a maintenance servicing task while cleaning the fluff grinder cyclone at the #3 extruder machine in the unit B area. The employer failed to implement energy control application steps as LOTO devices were not applied to the electrical disconnect [per the 1910.147(d)(4) requirements]. As a result, the remaining applicable energy control elements, involving dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from servicing hazards. prepare for shutdown [(d)(1)]; - ensure authorized employee has knowledge of the type, magnitude, the hazard, and the method or means to control the energy; shutdown the machine or equipment [(d)(2)]; machine isolation [(d)(3)]; physically locate and operate all energy isolating devices that are needed to control the energy to the machine or equipment in such a manner as to isolate the machine or equipment from the energy source(s); LOTO device application [(d)(4)]; affix a lockout or tagout device to each energy isolating device; dissipation of residual energy [(d)(5)(i)]; relieve, disconnect, restrain, and otherwise render safe all potentially hazardous stored or residual energy; verification of isolation [(d)(6)]; verify that isolation and deenergization of the machine or equipment has been accomplished;
Translate