Violation Detail
Standard Cited: 19100212 A03 II General requirements for all machines.
Inspection Nr: 1365251.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $9,282.00
Current Penalty: $6,000.00
Issuance Date: 03/06/2019
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 04/24/2019
Gravity: 10
Report ID: 0521400
Contest Date:
Final Order: 03/26/2019
Related Event Code (REC): A;R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/26/2019 | $6,000.00 | 04/24/2019 | Serious | |
| Penalty | Z: Issued | 03/06/2019 | $9,282.00 | 04/24/2019 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.212(a)(3)(ii): Point(s) of operation guards were not designed and constructed to prevent the operator from having any part of his/ her body in the danger zone during the operating cycle. On or about December 3, 2018, an employee received a right thumb amputation while operating a Relay Line Bender Machine inside the Relay Department and the employer did not ensure proper guarding was installed to eliminate amputation hazards near the point of operation. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).