Violation Detail
Standard Cited: 19100212 A01 General requirements for all machines.
Inspection Nr: 1361991.015
Citation: 01001
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $5,497.00
Current Penalty: $5,497.00
Issuance Date: 12/21/2018
Nr Instances: 1
Nr Exposed: 5
Abatement Date:
Gravity: 5
Report ID: 0523300
Contest Date:
Final Order: 01/18/2019
Related Event Code (REC): A;R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 12/21/2018 | $5,497.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about November 20, 2018, and at times prior to, machine guarding was not provided on the Betavac vacuum sealer (Serial No. NP19410-01) to protect operators from the pinch point hazard of the chamber lid lowering during each sealing cycle of the machine. The pinch point hazard was present because the safety ring switches on the chamber lid were not regularly maintained and adjusted to ensure that the safety function of these switches was maintained.