Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1359872.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $4,240.00
Current Penalty: $2,544.00
Issuance Date: 11/29/2018
Nr Instances: 5
Nr Exposed: 6
Abatement Date: 12/26/2018
Gravity: 1
Report ID: 0418100
Contest Date:
Final Order: 12/18/2018
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 12/18/2018 | $2,544.00 | 12/26/2018 | Serious | |
| Penalty | Z: Issued | 11/29/2018 | $4,240.00 | 12/26/2018 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a. 1000 SKC Drive, Covington, GA (Production Area -Slitter Machines) - The employees (maintenance) were exposed to sudden energization or start-up of multi-energy source machines. The employer did not have machine specific written procedures for locking out/tagging out the multi-energy machines to safe guard employees performing services and/or maintenance on machinery or equipment, on or about 11/14/18. a. Slitter L11 - 1361 b. Slitter L12 - 1362 c. Slitter L21 - 1363 d. Slitter L31 - 1364 e. Slitter L41
Translate