Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1358725.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $11,934.00
Current Penalty: $7,160.00
Issuance Date: 04/19/2019
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 06/14/2019
Gravity: 10
Report ID: 0524700
Contest Date:
Final Order: 04/25/2019
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/25/2019 | $7,160.00 | 06/14/2019 | Serious | |
| Penalty | Z: Issued | 04/19/2019 | $11,934.00 | 04/30/2019 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(d): The established procedures for the application of energy control (the lockout or tagout procedures) did not cover the following elements and actions and was not done in the following sequence. a. Casad Company, Inc. located in Coldwater, Ohio: On or about November 2, 2018, the employer did not ensure an employee responsible for servicing the small sublimator machine, Practix Mfg. Model OK10 located in the production department, properly lockout out the equipment prior to performing servicing work. As a result, the remaining applicable energy control elements, involving machine isolation[1910.147(d)(3)]. lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910.147(d)(5)(I)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine servicing hazards.