Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1340170.015
Citation: 01001
Citation Type: Serious
Abatement Status:
Initial Penalty: $12,934.00
Current Penalty: $0.00
Issuance Date: 10/12/2018
Nr Instances: 1
Nr Exposed: 10
Abatement Date: 10/23/2018
Gravity: 10
Report ID: 0524700
Contest Date:
Final Order: 11/07/2018
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/07/2018 | $0.00 | 10/23/2018 | Serious | |
Penalty | Z: Issued | 10/12/2018 | $12,934.00 | 10/23/2018 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: A) Materion Brush, Inc., located at 14710 West Portage River South Road, Elmore, OH 43416: On or about August 15, 2018, the employer did not properly train employees to lockout/tagout equipment such as, but not limited to, the Eitel Stroke Controlled Straightening Press # 1 (Type RP 60, Machine # 25374) prior to set-up activities. Employees conducted set-up activities such as, but not limited to, changing ram heads at the Eitel Press # 1 and were exposed to amputation hazards while all hazardous energy sources were not controlled prior to conducting work.