Violation Detail
Standard Cited: 19100252 C02 I C General requirements.
Inspection Nr: 1336141.015
Citation: 01001
Citation Type: Serious
Abatement Date: 03/15/2019 2
Initial Penalty: $3,031.00
Current Penalty: $2,274.00
Issuance Date: 01/24/2019
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 0111400
Contest Date:
Final Order: 02/19/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/19/2019 | $2,274.00 | 03/15/2019 | Serious | |
Penalty | Z: Issued | 01/24/2019 | $3,031.00 | 03/15/2019 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.252(c)(2)(i)(C): Mechanical ventilation was not provided in confined spaces or where the welding space contained partitions, balconies, or other structural barriers to the extent that they significantly obstructed cross ventilation: (a) Employees welding in a hopper were not provided mechanical ventilation exposing them to welding fumes.