Violation Detail
Standard Cited: 19100212 A01 General requirements for all machines.
Inspection Nr: 1335068.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $9,147.00
Current Penalty: $7,147.00
Issuance Date: 09/21/2018
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 10/04/2018
Gravity: 5
Report ID: 0524700
Contest Date:
Final Order: 10/12/2018
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/12/2018 | $7,147.00 | 10/04/2018 | Serious | |
| Penalty | Z: Issued | 09/21/2018 | $9,147.00 | 10/04/2018 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Phillips Tube Group (d.b.a. Shelby Welded Tube) located at 5578 State Route 61 North in Shelby, Ohio; On or about July 13, 2018 the employer did not ensure employees were protected from the shear point created between the Southworth Lift Table and the table of Mill 8. Employees were exposed to caught in and amputation hazards while re-energizing the Southworth Lift Table.
Translate