Violation Detail
Standard Cited: 19100147 C01 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1334368.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,174.00
Current Penalty: $3,550.00
Issuance Date: 09/26/2018
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 10/23/2018
Gravity: 5
Report ID: 0336000
Contest Date:
Final Order: 10/10/2018
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/10/2018 | $3,550.00 | 10/23/2018 | Serious | |
| Penalty | Z: Issued | 09/26/2018 | $5,174.00 | 10/23/2018 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury: a) Conrader Holdings, LLC at 749 E. 18th Street in Erie, PA. On or about July 31, 2018, an energy control program (lockout/tagout program) consisting of documented procedures, training, inspections/audits and lockout hardware had not been developed. Employees performed servicing and maintenance on machines .