Violation Detail
Standard Cited: 19100147 C04 II The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1326914.015
Citation: 01001
Citation Type: Serious
Abatement Status:
Initial Penalty: $7,853.00
Current Penalty: $0.00
Issuance Date: 10/17/2018
Nr Instances: 1
Nr Exposed: 10
Abatement Date: 11/05/2018
Gravity: 5
Report ID: 0317900
Contest Date:
Final Order: 11/13/2018
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/13/2018 | $0.00 | 11/05/2018 | Serious | |
| Penalty | Z: Issued | 10/17/2018 | $7,853.00 | 11/05/2018 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy: a) Production Work Area: On or about June 27, 2018, employees were performing maintenance and servicing work on production equipment, including completing jam clearance activities, but the energy control procedures for the equipment was not written in a manner that specifically detailed the steps and techniques necessary for safe deenergization of the equipment.