Violation Detail
Standard Cited: 19100217 C02 I B Mechanical power presses.
This violation item has been deleted.
Inspection Nr: 1318531.015
Citation: 01001
Citation Type: Serious
Abatement Status:
Initial Penalty: $10,163.00
Current Penalty: $0.00
Issuance Date: 11/16/2018
Nr Instances: 2
Nr Exposed: 10
Abatement Date: 01/10/2019
Gravity: 5
Report ID: 0524500
Contest Date:
Final Order: 12/12/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/12/2018 | $0.00 | 01/10/2019 | Serious | |
Penalty | Z: Issued | 11/16/2018 | $10,163.00 | 01/10/2019 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.217(c)(2)(i)(b): Point of operation guard(s) on mechanical power press(es) did not conform to the maximum permissible Opening(s) specified in Table 10 O-10: Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a. On or about May 22, 2018, employees working in the Press Department were exposed to the hazard of being caught in the point of operation while operating the Minster Press, Machine Number R-05, Model Number 40E-4 1/2, Serial Number 40-4.5E-5640, because the employer had not provided adequate machine guarding. b. On or about May 22, 2018, employees working in the Press Department were exposed to the hazard of being caught in the point of operation while operating the Minster Press, Machine Number R-03, Model Number 40E-4 1/2, Serial Number 6085, because the employer had not provided adequate machine guarding.