Violation Detail
Standard Cited: 19100212 A01 General requirements for all machines.
Inspection Nr: 1315002.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $11,641.00
Current Penalty: $11,641.00
Issuance Date: 08/28/2018
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 09/17/2018
Gravity: 10
Report ID: 0626700
Contest Date:
Final Order: 09/25/2018
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 08/28/2018 | $11,641.00 | 09/17/2018 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by rotating parts: a) On May 2, 2018 the Resina automatic capper machine model U40 with serial number 775544 did not had the chains and sprockets guarded, this causing an employee to crushed his right hand fingers.