Violation Detail
Standard Cited: 19100147 C04 II D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1311745.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,934.00
Current Penalty: $9,050.00
Issuance Date: 08/15/2018
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 10/05/2018
Gravity: 10
Report ID: 0524500
Contest Date:
Final Order: 09/04/2018
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 09/04/2018 | $9,050.00 | 10/05/2018 | Serious | |
| Penalty | Z: Issued | 08/15/2018 | $12,934.00 | 10/05/2018 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures: On or about April 20, 2018, employees were exposed to hazardous electrical and pneumatic energy sources while performing service and maintenance activities on the Hytrol Conveyor system and the energy control procedures did not specify where to apply lockout devices or provide instructions to verify that the energy was controlled and the machine was rendered safe.
Translate