Violation Detail
Standard Cited: 19100212 A02 General requirements for all machines.
Inspection Nr: 1311119.015
Citation: 01001
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $10,163.00
Current Penalty: $7,114.10
Issuance Date: 06/21/2018
Nr Instances: 1
Nr Exposed: 5
Abatement Date:
Gravity: 5
Report ID: 0729300
Contest Date:
Final Order: 07/17/2018
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/17/2018 | $7,114.10 | Serious | ||
Penalty | Z: Issued | 06/21/2018 | $10,163.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.212(a)(2): Guard on machine was not affixed to the machine or secured elsewhere when attachment to the machine was not possible: At the time of the inspection, it was determined that on 4/24/2018 the access door to the ELDAN cable stripper was not secured to prevent the operator from opening the door while the machine was in operation.