Violation Detail
Standard Cited: 19260403 B01 General requirements.
Inspection Nr: 1310686.015
Citation: 01001
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $4,268.00
Current Penalty: $2,987.60
Issuance Date: 08/31/2018
Nr Instances: 1
Nr Exposed: 5
Abatement Date:
Gravity: 10
Report ID: 0214500
Contest Date:
Final Order: 01/24/2019
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 01/24/2019 | $2,987.60 | Serious | ||
Penalty | Z: Issued | 08/31/2018 | $4,268.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees: Electrical cable was suspended +/- 25 feet over parking lot where truck traffic was present. a) Front Parking Lot: Employees were exposed to scaffold collapse from an electrical cable that was suspended over a parking lot where truck traffic was present. An incident occurred where the cable was caught by the bed of a dump truck, causing a scaffold to collapse injuring an employee, on or about 4-23-18.