Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1310286.015
Citation: 01001
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $11,641.00
Current Penalty: $6,402.00
Issuance Date: 09/24/2018
Nr Instances: 2
Nr Exposed: 2
Abatement Date:
Gravity: 10
Report ID: 0316400
Contest Date:
Final Order: 10/23/2018
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/23/2018 | $6,402.00 | Serious | ||
| Penalty | Z: Issued | 09/24/2018 | $11,641.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment (a) E-Line: Energy control procedures were not followed to ensure the equipment was at zero energy state prior to performing work.
Translate