Violation Detail
Standard Cited: 5A0001 OSH Act General Duty Paragraph
Inspection Nr: 1305884.015
Citation: 01001
Citation Type: Serious
Abatement Status: Not Completed - Employer Out of Business
Initial Penalty: $11,641.00
Current Penalty: $7,217.00
Issuance Date: 09/27/2018
Nr Instances: 8
Nr Exposed: 9
Abatement Date: 04/19/2019
Gravity: 10
Report ID: 0213900
Contest Date:
Final Order: 10/16/2018
Related Event Code (REC): C
Emphasis:
Substance: E200
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | P: Petition to Mod Abatement | 01/16/2019 | $7,217.00 | 04/19/2019 | Serious | |
Penalty | I: Informal Settlement | 10/16/2018 | $7,217.00 | 11/16/2018 | Serious | |
Penalty | Z: Issued | 09/27/2018 | $11,641.00 | 10/03/2018 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish the employees employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm in that employees were exposed to potential fire, deflagration and explosion hazards: a) Mill Work Area: The plastic flex hose connecting the Timesavers Incorporated sanding machine, model 137-1HD/60 serial number 24131F, to the wood dust collection system was not grounded or otherwise equipped to prevent the airflow from generating static electricity, on or about 4/3/18. b) Mill Work Area: The plastic flex hose connecting the Mikron 645 Multi Moulder serial number MRO449 to the wood dust collection system was not grounded or otherwise equipped to prevent the airflow from generating static electricity, on or about 4/3/18 c) Mill Work Area: The plastic flex hose connecting the Extrema shaper to the wood dust collection system was not grounded or otherwise equipped to prevent the airflow from generating static electricity, on or about 4/3/18. d) Mill Work Area: The plastic flex hose connecting the SCMI T110i to the wood dust collection system was not grounded or otherwise equipped to prevent the airflow from generating static electricity, on or about 4/3/18. e) Mill Work Area: The plastic flex hose connecting the Northtech Planar, model NT-24-10HCVS serial number 040423, to the wood dust collection system was not grounded or otherwise equipped to prevent the airflow from generating static electricity, on or about 4/3/18. f) Stair Mill Area: The plastic flex hose connecting the Powermatic table saw to the wood dust collection system was not grounded or otherwise equipped to prevent the airflow from generating static electricity, on or about 4/3/18. g) Interior Door Area: The plastic flex hoses connecting the Wise Door router machine, model 8800E serial number 8800E-148, to the wood dust collection system were not grounded or otherwise equipped to prevent the airflow from generating static electricity, on or about 4/3/18. h) Fabrication Department dust collection system: When air from the Murphy Rodgers Dust Collector model MRSE-16-4D serial number 1108 was allowed to recirculate back into the work area, the employer failed to ensure that it was equipped with a spark detection system and an abort gate to prevent a fire or explosion originating in the wood dust collector from re-entering the work area, on or about 4/3/18. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.