Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1305280.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,934.00
Current Penalty: $7,000.00
Issuance Date: 08/01/2018
Nr Instances: 7
Nr Exposed: 200
Abatement Date: 08/29/2018
Gravity: 10
Report ID: 0636900
Contest Date:
Final Order: 08/21/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/21/2018 | $7,000.00 | 08/29/2018 | Serious | |
Penalty | Z: Issued | 08/01/2018 | $12,934.00 | 08/29/2018 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section. The employer failed to develop and implement written lockout/tagout procedures for each type of machine located in the facility exposing employees to electrocution and amputation hazards.