Violation Detail
Standard Cited: 19100212 A03 II General requirements for all machines.
Inspection Nr: 1289024.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,148.00
Current Penalty: $4,888.80
Issuance Date: 02/09/2018
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 02/27/2018
Gravity: 10
Report ID: 0419400
Contest Date:
Final Order: 02/28/2018
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/28/2018 | $4,888.80 | 02/27/2018 | Serious | |
Penalty | Z: Issued | 02/09/2018 | $8,148.00 | 02/27/2018 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s). (a) Farrel Vertical Calender - On or about January 18, 2018 employees operated machine and the in-running rollers on the feed side and wind side were not guarded.