Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1282179.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,934.00
Current Penalty: $9,054.00
Issuance Date: 02/16/2018
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 05/17/2018
Gravity: 10
Report ID: 0112600
Contest Date:
Final Order: 03/07/2018
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/07/2018 | $9,054.00 | 05/17/2018 | Serious | |
Penalty | Z: Issued | 02/16/2018 | $12,934.00 | 05/17/2018 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: Proof Tester 43, OFS Fitel, 50 Hall Road, Sturbridge, Massachusetts; On and before December 11, 2017 the employer did not utilize the energy control procedure while threading the proof tester, exposing employees to crushing and amputation injuries during the setup operation.