Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1281732.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,691.00
Current Penalty: $3,130.00
Issuance Date: 01/26/2018
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 06/01/2018
Gravity: 5
Report ID: 0524700
Contest Date:
Final Order: 02/22/2018
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 02/22/2018 | $3,130.00 | 06/01/2018 | Serious | |
| Penalty | Z: Issued | 01/26/2018 | $5,691.00 | 03/14/2018 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: a) On or about December 6, 2017, the employer did not conduct annual audits of its energy control procedure to assure that proper lockout/tagout procedures and requirements were being followed. The lack of procedure audits exposed employees to injuries in that adequate machine isolation was not being followed when employees accessed hazard areas of machines while performing maintenance and servicing activities.