Violation Detail
Standard Cited: 19100023 B02 Ladders.
Inspection Nr: 1280748.015
Citation: 01001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $11,086.00
Current Penalty: $2,500.00
Issuance Date: 06/04/2018
Nr Instances: 2
Nr Exposed: 20
Abatement Date: 07/05/2018
Gravity: 5
Report ID: 0625500
Contest Date:
Final Order: 12/10/2021
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 12/10/2021 | $2,500.00 | 07/05/2018 | Other | |
| Penalty | Z: Issued | 06/04/2018 | $11,086.00 | 07/05/2018 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
1910.23(b)(2) (2) Ladder rungs, steps, and cleats are spaced not less than 10 inches (25 cm) and not more than 14 inches (36 cm) apart, as measured between the centerlines of the rungs, cleats, and steps, except that: OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of a fall: Tessman Road Landfill: On or about December 4, 2017, and at times prior thereto, employees were exposed to a fall hazard while climbing ladder rungs: a) That measured greater than 12 inches apart on an industrial roll-off steel waste container, and b) That had clearances from the outside surface of the rungs to the container that were not a minimum of 4 inches.