Violation Detail
Standard Cited: 19100147 C06 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1272858.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,543.00
Current Penalty: $5,543.00
Issuance Date: 02/01/2018
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 03/08/2018
Gravity: 1
Report ID: 0728500
Contest Date:
Final Order: 02/28/2018
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 02/01/2018 | $5,543.00 | 03/08/2018 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic (annual) inspections of energy control procedures were performed. The certification should identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection. An examination of program elements determined that periodic inspections of energy control procedures were not accomplished and certified. Specifically, reviews were not conducted to determine if listed steps were still adequate.