Violation Detail
Standard Cited: 19100217 E01 I C Mechanical power presses.
Inspection Nr: 1272490.015
Citation: 01001
Citation Type: Other
Abatement Date: 01/08/2018 2
Initial Penalty: $4,889.00
Current Penalty: $3,422.30
Issuance Date: 12/04/2017
Nr Instances: 3
Nr Exposed: 7
Related Event Code (REC):
Gravity:
Report ID: 0522500
Contest Date:
Final Order: 12/21/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/21/2017 | $3,422.30 | 01/08/2018 | Other | |
Penalty | Z: Issued | 12/04/2017 | $4,889.00 | 01/08/2018 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.217(e)(1)(i): Under the general component of the inspection program, the employer shall: 29 CFR 1910.217(e)(1)(i)(C): Maintain a certification record of each inspection, and each maintenance and repair task performed, under the general component of the inspection program that includes the date of the inspection, maintenance, or repair work, the signature of the person who performed the inspection, maintenance, or repair work, and the serial number, or other identifier, of the power press inspected, maintained, and repaired: a. On or before October 23, 2017, in the production/stamping area, the employer did not document the inspection activity for the quarterly PM inspections on the R2007 1200 ton Clearing press #7 including, but not limited to, the following: recording clutch/brake system data including brake stopping time, clutch time, adjustments, and replacements. b. On or before October 23, 2017, in the production/stamping area, the employer did not document and certify the daily inspections on the R2007 1200 ton Clearing press #7 including, but not limited to, the following: safe operating condition of the antirepeat feature and loose or missing guards on the two-hand controls. c. On or before October 23, 2017, in the production/stamping area, the employer did not document the inspection activity every 9 months for the parallel, gib clearance of press & lift test inspections on the R2007 1200 ton Clearing press #7 including, but not limited to, the following: recording indicator readings.