Violation Detail
Standard Cited: 19100179 J02 Overhead and gantry cranes.
Inspection Nr: 1270556.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,934.00
Current Penalty: $12,934.00
Issuance Date: 03/30/2018
Nr Instances: 1
Nr Exposed: 15
Abatement Date: 04/11/2018
Gravity: 10
Report ID: 0523400
Contest Date:
Final Order: 04/23/2018
Related Event Code (REC): A
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/23/2018 | $12,934.00 | 04/11/2018 | Serious | |
Penalty | Z: Issued | 03/30/2018 | $12,934.00 | 04/11/2018 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.179(j)(2): Overhead cranes were not inspected for defects on a daily basis for items including but not limited to; all functional operating mechanisms for maladjustment, deterioration or leakage of air or hydraulic systems and hooks: (a) L&R 25 Ton Over Head Crane (Serial No. 12745); West Bay South Corner: On or about October 16, 2017, the employer did not ensure that electrical connectors on the overhead crane were inspected to ensure proper installation and that the electrical connections were complete.