Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1269680.015
Citation: 01001
Citation Type: Serious
Abatement Date: 11/03/2017 2
Initial Penalty: $8,465.00
Current Penalty: $8,465.00
Issuance Date: 10/24/2017
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 5
Report ID: 0317900
Contest Date:
Final Order: 11/21/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 10/24/2017 | $8,465.00 | 11/03/2017 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: a) Fabricating Department - on or about October 5, 2017, the employer did not ensure shutdown of the Automatan Label Laminator, Machine number 501 was conducted in accordance with appropriate documented company procedure when employees un-jammed labels, resulting in an amputation.