Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 1269638.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,675.00
Current Penalty: $6,337.50
Issuance Date: 11/16/2017
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 12/06/2017
Gravity: 10
Report ID: 0626600
Contest Date:
Final Order: 12/07/2017
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 12/07/2017 | $6,337.50 | 12/06/2017 | Serious | |
| Penalty | Z: Issued | 11/16/2017 | $12,675.00 | 12/06/2017 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting. On or about October 04, 2017, in the stacker area, where employees were exposed to a caught-by hazard when working and walking by a rotating shafts on a B & K stacker system without a guard to cover the rotating horizontal shafts.