Violation Detail
Standard Cited: 19100029 B01 Fall protection systems and falling object protection-criteria and practices.
Inspection Nr: 1268013.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $4,989.00
Current Penalty: $3,000.00
Issuance Date: 01/23/2018
Nr Instances: 1
Nr Exposed: 8
Abatement Date: 01/31/2018
Gravity: 1
Report ID: 0213100
Contest Date: 02/20/2018
Final Order: 09/04/2018
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 09/04/2018 | $3,000.00 | 01/31/2018 | Serious | |
Penalty | C: Contested | 02/21/2018 | $4,989.00 | 01/31/2018 | Serious | |
Penalty | Z: Issued | 01/23/2018 | $4,989.00 | 01/31/2018 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.29(b)(1): The top edge height of top rails, or equivalent guardrail system members, were not 42 inches, plus or minus 3 inches, above the walking-working surface: a) Loading dock, on October 4, 2017, and at times prior, guardrails designed to protect against a 5 foot fall hazard were installed too low to be protective.