Violation Detail
Standard Cited: 19100181 E02 Derricks.
Inspection Nr: 1266258.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,934.00
Current Penalty: $12,934.00
Issuance Date: 02/02/2018
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 03/01/2018
Gravity: 10
Report ID: 0626000
Contest Date:
Final Order: 02/28/2018
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 02/28/2018 | $12,934.00 | 03/01/2018 | Serious | |
| Penalty | Z: Issued | 02/02/2018 | $12,934.00 | 03/01/2018 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
Cited Standard Amended to: 29 CFR 1910.181(e)(2): All anchorages were not approved by the appointed person: On September 25, 2017, employees performing servicing activity on an oil well rig were exposed to a struck-by hazard when the mobile rig collapsed. Recommended Abatement Action: 1. Follow Owner manual recommendation for the XJ450 work over rig, section I, part 2 mast assembly, paragraph 2.5 for: a) Guy Lines b) Guy anchor installation 2. Follow American Petroleum Institute (API) Recommended Practice (RP) 54, third edition, 2013, Occupational Safety for Oil and Gas Well Drilling and Servicing Operations Section 92. Derrick and Masts, 9.2.10, Prior to imposing any load on a derrick or mast, all required load guy lines shall be properly tensioned.