Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1263472.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,549.00
Current Penalty: $7,500.00
Issuance Date: 11/08/2017
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 12/28/2017
Gravity: 10
Report ID: 0134000
Contest Date:
Final Order: 11/30/2017
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/30/2017 | $7,500.00 | 12/28/2017 | Serious | |
| Penalty | Z: Issued | 11/08/2017 | $12,549.00 | 12/28/2017 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) Location - Roll Line #5: On or about 9/8/17, the established lock out procedure was not utilized when an employee was cleaning/lubricating a live drive chain on a conveyor system.