Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1260126.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,934.00
Current Penalty: $8,000.00
Issuance Date: 02/02/2018
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 02/14/2018
Gravity: 10
Report ID: 0521700
Contest Date:
Final Order: 02/12/2018
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/12/2018 | $8,000.00 | 02/14/2018 | Serious | |
Penalty | Z: Issued | 02/02/2018 | $12,934.00 | 02/14/2018 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: Water house area - On or about August 28, 2017, authorized employees were required to remove a jam of the plastic tray(s) and also clean the Collussi No. 1 and No. 2 machines. The written energy control program did not include step-by-step lockout procedures utilizing the new key system (modified trap key system). Employees were thereby exposed to the hazards of inadvertent start-up of the equipment