Violation Detail
Standard Cited: 19100147 C07 I B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1257306.015
Citation: 01001
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $12,934.00
Current Penalty: $12,934.00
Issuance Date: 02/15/2018
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 10
Report ID: 0215600
Contest Date:
Final Order: 03/14/2018
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 02/15/2018 | $12,934.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure: A.) On or about August 18, 2017 at 136-40 Springfield Boulevard, Springfield Gardens, NY 11413 (Local Sort Department) The employer failed to provide affected (i.e. singulator belt tender) employees effective hazardous energy recognition and machine operation training which resulted in the amputation of an employee's finger tip. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED