Violation Detail
Standard Cited: 19100212 A01 General requirements for all machines.
Inspection Nr: 1253973.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $11,641.00
Current Penalty: $5,800.00
Issuance Date: 01/09/2018
Nr Instances: 1
Nr Exposed: 8
Abatement Date: 01/29/2018
Gravity: 10
Report ID: 0523400
Contest Date:
Final Order: 01/29/2018
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/29/2018 | $5,800.00 | 01/29/2018 | Serious | |
| Penalty | Z: Issued | 01/09/2018 | $11,641.00 | 01/29/2018 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.212(a)(1): One or more methods of machine guarding were not provided to protect the operator, and others in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) RF Thermatron die cutting press: The employer did not insure adequate guarding was provided to prevent the operator from having any part of his body in the danger zone during the operating cycle. The lack of guarding exposed employees to in-going nip points, crushing hazards, and amputation injury related to mechanical operations which occur during machine cycles.