Powered by GoogleTranslate

Violation Detail

Standard Cited: 19100212 A01 General requirements for all machines.

Inspection Nr: 1252005.015

Citation: 01001

Citation Type: Serious

Abatement Status: Abatement Completed

Initial Penalty: $12,675.00

Current Penalty: $6,337.50

Issuance Date: 08/11/2017

Nr Instances: 5

Nr Exposed: 3

Abatement Date: 08/23/2017

Gravity: 10

Report ID: 0830300

Contest Date:

Final Order: 08/31/2017

Related Event Code (REC):

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty I: Informal Settlement 08/31/2017 $6,337.50 08/23/2017 Serious  
Penalty Z: Issued 08/11/2017 $12,675.00 08/23/2017 Serious  

Text For Citation: 01 Item/Group: 001 Hazard:

29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) On or about August 3, 2017 and at time prior to that date, for the employees exposed to caught-in and/or struck-by hazards where a Jet drill press, model no. JDP-125VS-3, serial no. 186223B was operated in the wet end maintenance shop at 3630 Gateway Drive, Grand Forks, North Dakota. (b) On or about July 28, 2017 and at time prior to that date, for the employees exposed to caught-in and/or struck-by hazards where a Exacto vertical milling machine, model no. 942B, serial no. 112939 was operated in the wet end maintenance shop at 3630 Gateway Drive, Grand Forks, North Dakota. (c) On or about July 28, 2017 and at time prior to that date, for the employees exposed to caught-in and/or struck-by hazards where a Jet lathe, model no. GHB-1340A, serial no. 08062048A was operated in the wet end maintenance shop at 3630 Gateway Drive, Grand Forks, North Dakota. (d) On or about July 28, 2017 and at time prior to that date, for the employees exposed to struck-by hazards where an OTC 55 ton hydraulic H-frame press was operated in the wet end maintenance shop at 3630 Gateway Drive, Grand Forks, North Dakota. (e) On or about August 3, 2017 and at time prior to that date, for the employees exposed to caught-in and/or struck-by hazards where a Delta drill press, model no. 1, serial no. 2007 33-XC was operated in the packaging maintenance shop at 3630 Gateway Drive, Grand Forks, North Dakota.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.