Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1249935.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,334.00
Current Penalty: $4,768.00
Issuance Date: 11/20/2017
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 12/08/2017
Gravity: 5
Report ID: 0213400
Contest Date:
Final Order: 12/14/2017
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 12/14/2017 | $4,768.00 | 12/08/2017 | Serious | |
| Penalty | Z: Issued | 11/20/2017 | $7,334.00 | 12/08/2017 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) 554 Waterworks Road, Old Bridge, NJ: The employer did not develop and implement machine specific energy control procedures where employees were required to perform servicing and maintenance on machines such as but not limited to the Zinc Sulfate bagging operation. This hazard was observed on 7/20/17.