Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1249605.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,149.00
Current Penalty: $4,482.00
Issuance Date: 08/01/2017
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 08/24/2017
Gravity: 5
Report ID: 0524700
Contest Date:
Final Order: 08/22/2017
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/22/2017 | $4,482.00 | 08/24/2017 | Serious | |
| Penalty | Z: Issued | 08/01/2017 | $8,149.00 | 08/24/2017 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): (a) DRW Packing, Inc. on or about July 20, 2017, at the address of 866 St. Rt. 162 E. North Fairfield, OH: The employer did not ensure the power transmitting belt and pulley(s) located on the Squash Cull Line mobile conveyor was adequately guarded. During operation, employees working on or near this unguarded nip-point were exposed to amputation hazards.
Translate