Violation Detail
Standard Cited: 19100106 E09 III Flammable liquids.
Inspection Nr: 1246890.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $1,630.00
Current Penalty: $1,141.00
Issuance Date: 07/27/2017
Nr Instances: 4
Nr Exposed: 3
Abatement Date: 09/13/2017
Gravity: 1
Report ID: 0112000
Contest Date:
Final Order: 08/23/2017
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/23/2017 | $1,141.00 | 09/13/2017 | Serious | |
| Penalty | Z: Issued | 07/27/2017 | $1,630.00 | 09/13/2017 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.106(e)(9)(iii): Combustible waste material and residues in a building or unit operating area were not kept to a minimum, stored in covered metal receptacles and disposed of daily: Print Room: On, or about, July 14, 2017, wipes that had been used with EasiSolv 120, a Category 3 flammable liquid, were disposed of into plastic 32 gallon trash receptacles.