Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1236802.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,675.00
Current Penalty: $10,140.00
Issuance Date: 09/12/2017
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 09/18/2017
Gravity: 10
Report ID: 0521700
Contest Date: 10/04/2017
Final Order: 02/06/2019
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 02/06/2019 | $10,140.00 | 09/18/2017 | Serious | |
Penalty | C: Contested | 10/12/2017 | $12,675.00 | 09/18/2017 | Serious | |
Penalty | Z: Issued | 09/12/2017 | $12,675.00 | 09/18/2017 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) did not cover the following elements and actions and was not done in the following sequence: a. On or about May 15, 2017, employees were exposed to machine hazards associated with nip points when they engaged in servicing and maintenance activities on equipment located in the Can Assembly Department. The employer did not ensure that employees implemented energy control application steps during set-up activities, exposing them to amputation injuries from chain and sprocket assemblies on Line 2. The machines were not shut down or turned off prior to engaging in these servicing and maintenance activity. As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147 (d)(4)], dissipation of residual energy [1910.147 (d)(5)(I)], and verification of isolation [1910.147 (d)(6)] were not implemented to protect employees from machine servicing hazards.