Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1228543.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,070.00
Current Penalty: $3,549.00
Issuance Date: 06/22/2017
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 07/19/2017
Gravity: 10
Report ID: 0524200
Contest Date:
Final Order: 07/11/2017
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 07/11/2017 | $3,549.00 | 07/19/2017 | Serious | |
| Penalty | Z: Issued | 06/22/2017 | $5,070.00 | 07/19/2017 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in the activities covered by this section: a) 1804 W. Central Road, Mount Prospect, IL, 60174 - On or about April 21, 2017, the employer did not ensure equipment-specific energy control procedures were utilized for the control of potentially hazardous energy during testing for electrical contact to an overhead door operator in Bay #3, which resulted in multiple bodily and facial injuries to two service technicians that were exposed to a fall hazard of approximately 14 feet while on a scissor lift.
Translate