Violation Detail
Standard Cited: 19100212 A03 II General requirements for all machines.
Inspection Nr: 1220340.015
Citation: 01001
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $12,548.00
Current Penalty: $9,000.00
Issuance Date: 04/18/2017
Nr Instances: 1
Nr Exposed: 3
Abatement Date:
Gravity: 10
Report ID: 0523400
Contest Date:
Final Order: 05/09/2017
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/09/2017 | $9,000.00 | Serious | ||
| Penalty | Z: Issued | 04/18/2017 | $12,548.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.212(a)(3)(ii): Point(s) of operation guards were not designed and constructed to prevent the operator from having any part of his/ her body in the danger zone during the operating cycle: (a) The employer did not ensure that the Merlin Light Curtain was properly programed with the cycling of the Accurpress Brake Press (Seherpress Sales, model no. 7606, serial no. 4573, company machine no. 38, maintenance machine no. 6ft 001) which caused employee exposure to caught-in-between hazards of the brake press.
Translate