Violation Detail

Standard Cited: 5A0001 OSH Act General Duty Paragraph

This violation item has been deleted.

Inspection Nr: 121991889

Citation: 01001

Citation Type: Serious

Abatement Status: W

Initial Penalty: $1,500.00

Current Penalty:

Issuance Date: 06/21/1999

Nr Instances: 1

Nr Exposed: 2

Abatement Date: 06/25/1999

Gravity: 10

Report ID: 0522000

Contest Date:

Final Order:

Related Event Code (REC):

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty I: Informal Settlement 07/07/1999 06/25/1999 Serious  
Penalty Z: Issued 06/21/1999 $1,500.00 06/25/1999 Serious  

Text For Citation: 01 Item/Group: 001 Hazard: CRUSHING

Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to crushing injuries due to being struck by falling portions of the building structure: (a) On the 9th of April, 1999, employees working under the front porch structure at a residential construction site were exposed to structural collapse hazards, due to inadequate bracing and supports to assure structural integrity under appropriate wind load conditions including the 58 mile per-hour winds to which it was exposed. Bracing and supports did not meet the recognized specifications for Minimum Design Loads for Buildings and Other Structures as required by the American National Standards Institute (ANSI), and American Society of Civil Engineers (ASCE 7-95), for requirements of dead, live, soil, flood, wind, snow rain, ice, and earthquake loads and their combinations, that are suitable for inclusion in building codes (as referenced in section 6-1 "Wind Loads", and those found in and in the 1989 edition, Council of American Building Officials (CABO), One and Two Family Dwelling Code which provides a minimum requirements to safeguard life or limb, health, and public welfare and the protection of property as it relates to these safeguards by regulating and controlling the design, construction, prefabrication, equipment or appliance installation, quality of materials, use and occupancy location and repair of detached one- or two-family dwellings, not more than three stories in height as referenced for "Fastening Schedule", Table 2305.2 Building Element 3, Roof and Ceiling Construction and design building design criteria an specifications in section 301.2 and table 301.2b. Among other methods, one feasible and acceptable method to abate this hazard is the installation and bracing of the structure in accordance with ANSI/ASCE and CABO specifications.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close