Violation Detail
Standard Cited: 19100147 C04 II D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1216492.015
Citation: 01001
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $9,054.00
Current Penalty: $6,000.00
Issuance Date: 04/17/2017
Nr Instances: 1
Nr Exposed: 15
Related Event Code (REC):
Gravity: 5
Report ID: 0524200
Contest Date:
Final Order: 05/09/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/09/2017 | $6,000.00 | Serious | ||
Penalty | Z: Issued | 04/17/2017 | $9,054.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures. a) Die Casting Area- On or about April 4, 5, 6, 2017, the employer failed to create energy control procedures that clearly and specifically outlined the requirements for testing machines and equipment, such as Die Casting Machines #5 and #18, to determine and verify the effectiveness of the lockout devices that were applied. No abatement certification or documentation is required for this item.