Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1212484.015
Citation: 01001
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $12,675.00
Current Penalty: $8,872.00
Issuance Date: 05/10/2017
Nr Instances: 3
Nr Exposed: 10
Related Event Code (REC):
Gravity: 10
Report ID: 0418100
Contest Date:
Final Order: 05/25/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/25/2017 | $8,872.00 | Serious | ||
Penalty | Z: Issued | 05/10/2017 | $12,675.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about 2/23/2017 in the Upper Revent Mixing and Main Line Mixing Room(s) at 134 Elder Street, Bogart, GA: Where employees were engaged in sanitation service and maintenance on the equipment such as but not limited to Pan Washer, Surry Mixers, and Likifier , locks, and or tags were not utilized on all of the energy sources.